Name | Calman Carotid Clamp |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Lexis Industry |
Sterility | Non-Sterile |
Usage | Reusable |
Calman Carotid Clamp
Calman Carotid Clamp
angled shanks, long thin jaw, 25.0 mm, 4-1/4″ (11.0 cm)
Calman Carotid Clamp is ideally suited for use in cardiothoracic surgical procedures specifically in surgeries that require clamping of the carotid vessels. This clamp feature angled shanks to increase the easy of access to the vessels as well as having a long thing jaw that allows it to move between deeper layers of tissue without displacing anything or injuring other organs of vasculature. This clamp is strong enough to provide the occluding force necessary but also is gentle enough to keep the carotid walls intact with minimal injury or bruising.
SKU:
BF-8397
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Calman Carotid Clamp” Cancel reply
Shipping & Delivery
Related products
Castaneda Clamp
Castaneda Clamp
curved shanks, long thin jaw, calibrated jaws, horizontal serrations, 6" (15.0 cm)
Cataneda Clamp is a versatile tool made for use in cardiothoracic surgical procedures for newborn babies. This clamps are designed for neonatal use and as much are much smaller than their traditional counterpart but are equally effective. This multipurpose clamp is designed with curved shanks as well as long thing calibrated jaws coupled with horizontal serrations. Additionally, this instrument is available at varying angles and as a multi purpose or partially occluding clamp making it easy to find a perfect fit for any surgical procedure.
Cooley Patent Ductus Clamp – 6 1/4″
Cooley Patent Ductus Clamp - 6 1/4"
jaws calibrated at 5.0 mm intervals, 6-1/4" (16.0 cm)
Cooley Patent Ductus clamp is well suited for use in cardiothoracic surgical procedures. Specifically this clamp is designed for use in surgical procedures to repair a patent ductus. The jaws of this clamp are calibrated at 5 mm intervals and are designed for a firm surgical grip upon the vessels but is delicate enough to prevent any bruising or tears to the vessels walls themselves. This instrument is available with either straight or angular shanks making it possible to select the best fit possible for the procedure at hand.
Cooley Anastomosis Clamp
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Cooley Coarctation Clamp – 9 3/4″
Cooley Coarctation Clamp - 9 3/4"
7.0 cm long straight jaws, straight shanks, 9-3/4" (24.8 cm)
Cooley Coractation Clamp is well suited for use in cardiothoracic surgical procedures that necessitate total or partial occlusion of a vessel. This is often done in cardiothoracic surgical procedures to prevent the patients from losing an excessive amount of blood during surgery. This pattern features longer jaws and a longer overall length for cases where additional reach is necessary, as well as straight jaws and shanks which are designed to provide a firm and stable grip once they have been affixed to the site where the clamping is needed.
Exclusion Clamp
Exclusion Clamp
s shaped, curved jaws 8.5 cm, 7-1/4" (18.5 cm)
Aortic Exclusion Clamp are ideally made for use in cardiothoracic surgical procedures in which there is a need to exclude a certain portion of the aorta. The unique "S" shaped curvature of the jaws makes it contoured to fit the unique curvature and shapes necessary of atraumatic clamping of vessels. Although this instrument could have a wide application on other vessels it is designed for use in clamping of the aorta. This instrument is comprised of premium German operating-room grade stainless steel.
Cooley Acutely Curved Clamp
Cooley Acutely Curved Clamp
angled shanks, jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Acutely Curved Clamp is designed for use in cardiothoracic surgeries. This instrument is designed to clamp vessels to reduce or completely block blood flow during surgery to allow the procedure to continue in a certain anatomical location where the blood is no longer able to flow through. These clamps feature an angled shanks as well as jaws calibrate at 5 mm intervals. Additionally, this instrument is available in three sizes: small, medium and large to accommodate a variety of patient sizes and a the wide variety of vessels that this clamp can be used on.
Cooley Iliac Clamp
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Cooley Aortic Aneurysm Clamp
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Reviews
There are no reviews yet.