Name | CV Elite – Titanium Debakey Micro Clamp |
Lead Time | LEAD TIME ADVISED WITHIN 48 HOURS OF ORDER PLACEMENT. |
Specialty | Cardiothoracic-Clamps-Titanium Vascular Clamps – Delicate Clamps |
Material Finish | Titanium |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Lexis Industry |
Sterility | Non-Sterile |
Usage | Reusable |
Titanium Debakey Micro Clamp
Titanium Debakey Micro Clamp
debakey jaws
Titanium DeBakey Micro Clamp is used most commonly for cardiothoracic surgeries to clamp smaller vessels. The clamp’s titanium composition makes it both lighter and stronger than the competition, reducing hand strain, as well as making it non-magnetic. The jaws are serrated with DeBakey teeth for gentle yet effective clamping. The clamp comes in a wide variety of small jaws sizes and angle configurations to match different surgeon and procedure needs.
SKU:
BF-4211
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Titanium Debakey Micro Clamp” Cancel reply
Shipping & Delivery
Related products
Cooley Pediatric Clamp
Cooley Pediatric Clamp
delicate clamp, jaws calibrated at 5.0 mm intervals, 5-1/2" (14.0 cm)
Cooley Pediatric Clamp is ideally suited for clamping in cardiothoracic surgical procedures with pediatric patients. This clamp features jaws that are calibrated at 5.0 mm intervals but are still delicate enough for use in pediatric surgeries. This instrument is designed to keep a firm hold on the vessels that are being occluded but delicate enough not to bruise or tear the vessels thus reducing the amount of damage done to the patient. This clamp is available in a number of different styles that include straight or angled shanks and straight, satinsky, angled, or spoon-shaped jaws making this instrument highly versatile and useful in the operating room.
Exclusion Clamp
Exclusion Clamp
s shaped, curved jaws 8.5 cm, 7-1/4" (18.5 cm)
Aortic Exclusion Clamp are ideally made for use in cardiothoracic surgical procedures in which there is a need to exclude a certain portion of the aorta. The unique "S" shaped curvature of the jaws makes it contoured to fit the unique curvature and shapes necessary of atraumatic clamping of vessels. Although this instrument could have a wide application on other vessels it is designed for use in clamping of the aorta. This instrument is comprised of premium German operating-room grade stainless steel.
Castaneda Clamp
Castaneda Clamp
curved shanks, long thin jaw, calibrated jaws, horizontal serrations, 6" (15.0 cm)
Cataneda Clamp is a versatile tool made for use in cardiothoracic surgical procedures for newborn babies. This clamps are designed for neonatal use and as much are much smaller than their traditional counterpart but are equally effective. This multipurpose clamp is designed with curved shanks as well as long thing calibrated jaws coupled with horizontal serrations. Additionally, this instrument is available at varying angles and as a multi purpose or partially occluding clamp making it easy to find a perfect fit for any surgical procedure.
Bailey Aorta Clamp
Bailey Aorta Clamp
angled shanks
Bailey Aorta Clamp are designed for use in cardiothoracic surgical procedures. This clamp is ideal for use when there is a surgical maneuver that requires exclusion of a specific portion of the vessel. The unique design of this clamp with the slightly angled shanks allows for this clamp to effectively reach and clamp off the aorta when other instruments may not be able to. Additionally, this instrument is available in three different jaw sizes: extra small, small and large making it well suited for a number of different vessel sizes but also in different levels of blood flow restriction.
Cooley Cardiovascular Clamp – Fully-Curved
Fully-Curved
for temporary occulation of the iliac artery, 2-3/4" (7.0 cm) fully-curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is ideally suited for use in cardiothoracic surgical procedures that require temporary occultation of the iliac artery. This instrument comes equipped with fully curved jaws making it particularly well suited for use in clamping vessels close to the diameter of the iliac vessels. The scissor grip handles and the ratcheting mechanism for keeping the clamp in place allows for this clamp to stay securely in place through the surgical procedure but is gentle enough to keep from injuring the vessel walls.
Cooley Coarctation Clamp – 9 3/4″
Cooley Coarctation Clamp - 9 3/4"
7.0 cm long straight jaws, straight shanks, 9-3/4" (24.8 cm)
Cooley Coractation Clamp is well suited for use in cardiothoracic surgical procedures that necessitate total or partial occlusion of a vessel. This is often done in cardiothoracic surgical procedures to prevent the patients from losing an excessive amount of blood during surgery. This pattern features longer jaws and a longer overall length for cases where additional reach is necessary, as well as straight jaws and shanks which are designed to provide a firm and stable grip once they have been affixed to the site where the clamping is needed.
Cooley Renal Artery Clamp
Cooley Renal Artery Clamp
Cooley Renal Artery clamp is ideally suited for use in cardiothoracic surgeries. The slightly curved shanks and angled jaws make this clamp perfect for its ideal use which is as a renal clamp to fully or partially cause occlusion of the renal vessels. These jaws are atraumatic thus reducing injury and stress to the vessel walls while still remaining firmly in their affixed location. This instrument is available in three sizes: 7.25", 7.5" and 10.75" to accommodate a number of different surgical approaches and surgeon preferences.
Cooley Acutely Curved Clamp
Cooley Acutely Curved Clamp
angled shanks, jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Acutely Curved Clamp is designed for use in cardiothoracic surgeries. This instrument is designed to clamp vessels to reduce or completely block blood flow during surgery to allow the procedure to continue in a certain anatomical location where the blood is no longer able to flow through. These clamps feature an angled shanks as well as jaws calibrate at 5 mm intervals. Additionally, this instrument is available in three sizes: small, medium and large to accommodate a variety of patient sizes and a the wide variety of vessels that this clamp can be used on.
Reviews