Name | Dale Improved Femoral Popliteal Anastomosis Clamp |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Lexis Industry |
Sterility | Non-Sterile |
Usage | Reusable |
Popliteal Anastomosis Clamp
Popliteal Anastomosis Clamp
debakey jaws, jaws 4.0 cm, 7-1/4″ (18.5 cm)
Dale Improved Femoral Popliteal Anastomosis clamp is ideally suited for use in cardiothoracic surgical procedures. This is a highly versatile vascular clamp that can be used in procedures requiring a femoral popliteal anastomosis. Additionally, this clamp can be used when a broken-back small vascular clamp is required. This instrument is hand-crafted by certified instrument makers to conform to the highest standards in instrumentation.
SKU:
BF-1939
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Popliteal Anastomosis Clamp” Cancel reply
Shipping & Delivery
Related products
Cooley Anastomosis Clamp Modified
Anastomosis Clamp Modified
30 degree side angled jaws, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp Modified is ideally used in cardiothoracic surgeries that require anastomosis between vessels and thus a clamp is utilized to reduce but not completely occlude blood flow. This instrument is hand-crafted by certified instrument makers to conform to the highest standards in instrumentation. Additionally, this modified anastomosis clamp features a 30 degree side angled jaw making it more able to access harder to reach vessels.
Cooley Aorta Clamp
Cooley Aorta Clamp
Cooley Aorta Clamp is ideally suited for some cardiothoracic surgeries. This clamp is designed with a slight U-shaped hook shape to make a perfect tool for manipulation and clamping of the aorta. Additionally, these clamps are well suited for use in sectioning a specific portion of the aorta because they are created for easy handle a firm grip without causing any injury or damage to the vessel itself. This instrument is available in two different jaw lengths to make it suitable for use in a wide number of patients and surgeon preferences.
Cooley Occlusion Clamp
Cooley Occlusion Clamp
curved jaws, jaws 3.6 cm long
Cooley Occlusion Clamp is designed for use in cardiothoracic surgical procedures. This clamp can be used to clamp vessels to reduce or stop blood flow to prevent the patient from losing an excessive amount of blood. The jaws allow for firm grasp of the vessels but with reduced risk of crushing or bruising to the vessel wall. Additionally, this clamp features curved shanks and jaws giving them a contour more suitable for use in vascular surgical procedures. This instrument is available in two different lengths to accommodate different vessel sizes and positions.
Cherry Supraceliac Clamp
Cherry Supraceliac Clamp
shanks curved 60 degrees, debakey 2x3 teeth, jaws 5-3/4", curved, 12-1/2" (31.0 cm)
Cheery Supraceliac Clamp is created to be of optimal use in cardiothoracic surgical procedures. This instrument is especially useful aortic aneurysm repairs of the abdominal and thoracic aorta particularly this clamp can be used in accessing the portion of the aorta that is found superior to the celiac artery. Curved shanks coupled with a 60 degree angle and DeBakey teeth allow this clamp to access some deeper vessel structures without damaging the vessel walls or the surrounding tissue.
Calman Carotid Clamp
Calman Carotid Clamp
angled shanks, long thin jaw, 25.0 mm, 4-1/4" (11.0 cm)
Calman Carotid Clamp is ideally suited for use in cardiothoracic surgical procedures specifically in surgeries that require clamping of the carotid vessels. This clamp feature angled shanks to increase the easy of access to the vessels as well as having a long thing jaw that allows it to move between deeper layers of tissue without displacing anything or injuring other organs of vasculature. This clamp is strong enough to provide the occluding force necessary but also is gentle enough to keep the carotid walls intact with minimal injury or bruising.
Beck Miniature Aorta Clamp – Titanium
Titanium
straight shanks, 6-3/4" (17.0 cm), debakey jaws, titanium
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Exclusion Clamp
Exclusion Clamp
s shaped, curved jaws 8.5 cm, 7-1/4" (18.5 cm)
Aortic Exclusion Clamp are ideally made for use in cardiothoracic surgical procedures in which there is a need to exclude a certain portion of the aorta. The unique "S" shaped curvature of the jaws makes it contoured to fit the unique curvature and shapes necessary of atraumatic clamping of vessels. Although this instrument could have a wide application on other vessels it is designed for use in clamping of the aorta. This instrument is comprised of premium German operating-room grade stainless steel.
Cooley Iliac Clamp
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Reviews
There are no reviews yet.