Name | CV Elite – Titanium Castaneda Clamp – Debakey Jaws |
Lead Time | LEAD TIME ADVISED WITHIN 48 HOURS OF ORDER PLACEMENT. |
Specialty | Cardiothoracic-Clamps-Titanium Vascular Clamps – Delicate Clamps |
Material Finish | Titanium |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Lexis Industry |
Sterility | Non-Sterile |
Usage | Reusable |
Titanium Castaneda Clamp – Debakey Jaws
Double-angled calibrated debakey jaws, 7-1/2″ (19.0 cm), carotid clamp
Titanium Castaneda Clamp is a clamp generally used for grasping the carotid and other arteries in delicate fields during cardiovascular surgery. The clamp is made of blue-anodized titanium, a metal that is stronger and lighter than steel and also non-magnetic. It features specially calibrated DeBakey jaws designed for atraumatic occlusion of the carotid artery. The double-angled jaw configuration allows this clamp to maneuver effectively and clamp obscured arteries in the surgical field.
SKU:
BF-2917
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Titanium Castaneda Clamp – Debakey Jaws” Cancel reply
Shipping & Delivery
Related products
Cooley Iliac Clamp
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Beck Vascular Clamp
Beck Vascular Clamp
cooley jaws calibrated at 5.0 mm intervals, straight shanks, 6" (15.0 cm)
Beck Vascular Clamp is suited for optimal use in cardiothoracic surgical procedures. This clamp is designed to clamp vessels and occlude blood flow during surgical procedures in many cases to prevent an excessive amount of blood loss from the patient. A unique feature of this clamp is the curved Cooley jaws that are calibrated at 50 mm intervals as well as the straight shanks. This instrument is available two sizes: small jaw with heavy curvature and large jaw with medium curvature.
Cooley Aorta Clamp
Cooley Aorta Clamp
Cooley Aorta Clamp is ideally suited for some cardiothoracic surgeries. This clamp is designed with a slight U-shaped hook shape to make a perfect tool for manipulation and clamping of the aorta. Additionally, these clamps are well suited for use in sectioning a specific portion of the aorta because they are created for easy handle a firm grip without causing any injury or damage to the vessel itself. This instrument is available in two different jaw lengths to make it suitable for use in a wide number of patients and surgeon preferences.
Exclusion Clamp
Exclusion Clamp
s shaped, curved jaws 8.5 cm, 7-1/4" (18.5 cm)
Aortic Exclusion Clamp are ideally made for use in cardiothoracic surgical procedures in which there is a need to exclude a certain portion of the aorta. The unique "S" shaped curvature of the jaws makes it contoured to fit the unique curvature and shapes necessary of atraumatic clamping of vessels. Although this instrument could have a wide application on other vessels it is designed for use in clamping of the aorta. This instrument is comprised of premium German operating-room grade stainless steel.
Cooley Anastomosis Clamp
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Beck Miniature Aorta Clamp – Titanium
Titanium
straight shanks, 6-3/4" (17.0 cm), debakey jaws, titanium
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Cooley Occlusion Clamp
Cooley Occlusion Clamp
curved jaws, jaws 3.6 cm long
Cooley Occlusion Clamp is designed for use in cardiothoracic surgical procedures. This clamp can be used to clamp vessels to reduce or stop blood flow to prevent the patient from losing an excessive amount of blood. The jaws allow for firm grasp of the vessels but with reduced risk of crushing or bruising to the vessel wall. Additionally, this clamp features curved shanks and jaws giving them a contour more suitable for use in vascular surgical procedures. This instrument is available in two different lengths to accommodate different vessel sizes and positions.
Bailey Aorta Clamp
Bailey Aorta Clamp
angled shanks
Bailey Aorta Clamp are designed for use in cardiothoracic surgical procedures. This clamp is ideal for use when there is a surgical maneuver that requires exclusion of a specific portion of the vessel. The unique design of this clamp with the slightly angled shanks allows for this clamp to effectively reach and clamp off the aorta when other instruments may not be able to. Additionally, this instrument is available in three different jaw sizes: extra small, small and large making it well suited for a number of different vessel sizes but also in different levels of blood flow restriction.
Reviews
There are no reviews yet.